EPA 40 CFR PART 355 APPENDIX A // OFFICIAL EHS PROFILE

CAS 10025-87-3

Phosphorus Oxychloride (CAS 10025-87-3) EPA Tier II & EHS Threshold Guide

Phosphorus Oxychloride (CAS 10025-87-3) is an EPA Extremely Hazardous Substance (EHS) regulated under EPCRA Sections 302, 304, and 312. Facilities storing 500 lbs or more on-site at any single time during the calendar year must include Phosphorus Oxychloride in their annual March 1 Tier II chemical inventory report.

CAS Registry / EPA ID
10025-87-3
EPCRA Sec. 312 Tier II Limit
500 lb
EPCRA Sec. 302 TPQ
500 lb
CERCLA / Sec. 304 RQ
1,000 lb
Industrial Hazard Class
Organophosphates & Pesticides
Quick Mixture Threshold Calculator for Phosphorus Oxychloride
CAS 10025-87-3 · Tier II 500 lb

Enter your total product weight (or gallons × SG) and SDS Section 3 percentage for CAS 10025-87-3 to see whether federal EPCRA Section 302/312 reporting is triggered.

FILING REQUIRED — EHS TPQ/500 lb Triggered
EPA Range 04 (1,000 – 4,999 lbs)
Pure EHS Component Weight
500 lb
EPCRA Section 302 (TPQ Emergency Planning)
TRIGGERED
Tier II %
100%

How to Compile & File Phosphorus Oxychloride for EPA Tier II

  1. 1Locate CAS 10025-87-3 in Section 3 of every supplier Safety Data Sheet (SDS) across your facility—including diluted cleaners, battery electrolytes, water-treatment blends, or intermediates.
  2. 2Multiply each product's maximum on-site daily pounds (or gallons × SG × 8.345) by the upper-bound % concentration of Phosphorus Oxychloride, then sum all contributions across the entire facility.
  3. 3If total pure Phosphorus Oxychloride reaches 500 lbs (or total mixture weight reaches 10,000 lbs), export EPA Tier2 Submit XML and your state portal schedule via Tier2Ready before March 1.

Phosphorus Oxychloride (CAS 10025-87-3) Tier II Reporting FAQ

What is the EPA Tier II reporting threshold for Phosphorus Oxychloride (CAS 10025-87-3)?

The federal EPCRA Section 312 Tier II reporting threshold for Phosphorus Oxychloride (CAS 10025-87-3) is 500 lbs—calculated as the lesser of 500 lbs or its 40 CFR Part 355 Threshold Planning Quantity (500 lbs). State programs such as CA CERS or NJ CRTK may enforce lower thresholds.

What are the EPCRA Section 302 TPQ and CERCLA RQ for Phosphorus Oxychloride?

Phosphorus Oxychloride carries an EPA EPCRA Section 302 Threshold Planning Quantity (TPQ) of 500 lbs and a CERCLA / EPCRA Section 304 Reportable Quantity (RQ) of 1,000 lbs for accidental release notification.

Do I have to count Phosphorus Oxychloride if it is part of a chemical mixture?

Yes. Under 40 CFR 370.14, you must multiply each mixture's maximum on-site weight by the upper-bound weight percentage of CAS 10025-87-3 from SDS Section 3 and aggregate every container across the facility against the 500 lb EHS threshold.

Related EPA EHS Chemicals

Check Your State's Tier II Portal

Some states (like CA, NJ, LA, OR, VT) impose stricter state reporting thresholds or require TX STEERS, CA CERS, or E-Plan filing instead of .t2s desktop files.

Have multiple supplier SDS PDFs containing Phosphorus Oxychloride?

Upload up to 15 supplier SDS PDFs or an inventory CSV into Tier2Ready Workbench to auto-aggregate CAS 10025-87-3 across all mixtures and export EPA Tier2 Submit XML + 50-state portal sheets.