EPA 40 CFR PART 355 APPENDIX A // OFFICIAL EHS PROFILE

CAS 12002-03-8

Paris Green (CAS 12002-03-8) EPA Tier II & EHS Threshold Guide

Paris Green (CAS 12002-03-8) is an EPA Extremely Hazardous Substance (EHS) regulated under EPCRA Sections 302, 304, and 312. Facilities storing 500 lbs or more on-site at any single time during the calendar year must include Paris Green in their annual March 1 Tier II chemical inventory report.

CAS Registry / EPA ID
12002-03-8
EPCRA Sec. 312 Tier II Limit
500 lb
EPCRA Sec. 302 TPQ
500/10,000 lb
CERCLA / Sec. 304 RQ
1 lb
Industrial Hazard Class
Specialty 40 CFR 355 EHS
Dual Solid TPQ Applies (500/10,000 lbs)

Because Paris Green is a solid with a dual TPQ (500/10,000 lbs), the lower 500 lb TPQ applies when stored as fine powder (<100 µm), in solution, or molten. Non-powder solid forms use the 10,000 lb TPQ for Section 302 planning; always verify physical form against your supplier SDS Section 9.

Quick Mixture Threshold Calculator for Paris Green
CAS 12002-03-8 · Tier II 500 lb

Enter your total product weight (or gallons × SG) and SDS Section 3 percentage for CAS 12002-03-8 to see whether federal EPCRA Section 302/312 reporting is triggered.

FILING REQUIRED — EHS TPQ/500 lb Triggered
EPA Range 04 (1,000 – 4,999 lbs)
Pure EHS Component Weight
500 lb
EPCRA Section 302 (TPQ Emergency Planning)
TRIGGERED
Tier II %
100%

How to Compile & File Paris Green for EPA Tier II

  1. 1Locate CAS 12002-03-8 in Section 3 of every supplier Safety Data Sheet (SDS) across your facility—including diluted cleaners, battery electrolytes, water-treatment blends, or intermediates.
  2. 2Multiply each product's maximum on-site daily pounds (or gallons × SG × 8.345) by the upper-bound % concentration of Paris Green, then sum all contributions across the entire facility.
  3. 3If total pure Paris Green reaches 500 lbs (or total mixture weight reaches 10,000 lbs), export EPA Tier2 Submit XML and your state portal schedule via Tier2Ready before March 1.

Paris Green (CAS 12002-03-8) Tier II Reporting FAQ

What is the EPA Tier II reporting threshold for Paris Green (CAS 12002-03-8)?

The federal EPCRA Section 312 Tier II reporting threshold for Paris Green (CAS 12002-03-8) is 500 lbs—calculated as the lesser of 500 lbs or its 40 CFR Part 355 Threshold Planning Quantity (500/10,000 lbs). State programs such as CA CERS or NJ CRTK may enforce lower thresholds.

What are the EPCRA Section 302 TPQ and CERCLA RQ for Paris Green?

Paris Green carries an EPA EPCRA Section 302 Threshold Planning Quantity (TPQ) of 500/10,000 lbs and a CERCLA / EPCRA Section 304 Reportable Quantity (RQ) of 1 lbs for accidental release notification.

Do I have to count Paris Green if it is part of a chemical mixture?

Yes. Under 40 CFR 370.14, you must multiply each mixture's maximum on-site weight by the upper-bound weight percentage of CAS 12002-03-8 from SDS Section 3 and aggregate every container across the facility against the 500 lb EHS threshold.

Related EPA EHS Chemicals

Check Your State's Tier II Portal

Some states (like CA, NJ, LA, OR, VT) impose stricter state reporting thresholds or require TX STEERS, CA CERS, or E-Plan filing instead of .t2s desktop files.

Have multiple supplier SDS PDFs containing Paris Green?

Upload up to 15 supplier SDS PDFs or an inventory CSV into Tier2Ready Workbench to auto-aggregate CAS 12002-03-8 across all mixtures and export EPA Tier2 Submit XML + 50-state portal sheets.

Paris Green (CAS 12002-03-8) — EPA Tier II Threshold (500 lb) & EHS TPQ | Tier2Ready