EPA 40 CFR PART 355 APPENDIX A // OFFICIAL EHS PROFILE
CAS 75-21-8Ethylene Oxide (CAS 75-21-8) EPA Tier II & EHS Threshold Guide
Ethylene Oxide (CAS 75-21-8) is an EPA Extremely Hazardous Substance (EHS) regulated under EPCRA Sections 302, 304, and 312. Facilities storing 500 lbs or more on-site at any single time during the calendar year must include Ethylene Oxide in their annual March 1 Tier II chemical inventory report.
- [f] High-production-volume / acute lethality chemical of concern retained on the original EHS list.
Enter your total product weight (or gallons × SG) and SDS Section 3 percentage for CAS 75-21-8 to see whether federal EPCRA Section 302/312 reporting is triggered.
How to Compile & File Ethylene Oxide for EPA Tier II
- 1Locate CAS 75-21-8 in Section 3 of every supplier Safety Data Sheet (SDS) across your facility—including diluted cleaners, battery electrolytes, water-treatment blends, or intermediates.
- 2Multiply each product's maximum on-site daily pounds (or gallons × SG × 8.345) by the upper-bound % concentration of Ethylene Oxide, then sum all contributions across the entire facility.
- 3If total pure Ethylene Oxide reaches 500 lbs (or total mixture weight reaches 10,000 lbs), export EPA Tier2 Submit XML and your state portal schedule via Tier2Ready before March 1.
Ethylene Oxide (CAS 75-21-8) Tier II Reporting FAQ
What is the EPA Tier II reporting threshold for Ethylene Oxide (CAS 75-21-8)?
The federal EPCRA Section 312 Tier II reporting threshold for Ethylene Oxide (CAS 75-21-8) is 500 lbs—calculated as the lesser of 500 lbs or its 40 CFR Part 355 Threshold Planning Quantity (1,000 lbs). State programs such as CA CERS or NJ CRTK may enforce lower thresholds.
What are the EPCRA Section 302 TPQ and CERCLA RQ for Ethylene Oxide?
Ethylene Oxide carries an EPA EPCRA Section 302 Threshold Planning Quantity (TPQ) of 1,000 lbs and a CERCLA / EPCRA Section 304 Reportable Quantity (RQ) of 10 lbs for accidental release notification.
Do I have to count Ethylene Oxide if it is part of a chemical mixture?
Yes. Under 40 CFR 370.14, you must multiply each mixture's maximum on-site weight by the upper-bound weight percentage of CAS 75-21-8 from SDS Section 3 and aggregate every container across the facility against the 500 lb EHS threshold.
Related EPA EHS Chemicals
Some states (like CA, NJ, LA, OR, VT) impose stricter state reporting thresholds or require TX STEERS, CA CERS, or E-Plan filing instead of .t2s desktop files.
Upload up to 15 supplier SDS PDFs or an inventory CSV into Tier2Ready Workbench to auto-aggregate CAS 75-21-8 across all mixtures and export EPA Tier2 Submit XML + 50-state portal sheets.